Boilers · June 10, 2026 · 5 min read

Boiler Maintenance Tips for Alaska Homes

Check system pressure monthly during the heating season, bleed air from high points, verify the expansion tank charge and circulator operation annually, and have combustion analysis done every year before the season starts.

Blog / Boilers · By Moore Heating Service Team

Quick Facts

  • Typical cold-fill pressure: 12 to 15 psi
  • Bleed air from high points each fall
  • Expansion tank charge should match fill pressure
  • Glycol needs annual concentration testing
  • Annual combustion analysis is not optional
  • Boiler life: 20 to 30 years with care

Pressure, Temperature, and Air

Most hydronic complaints trace back to one of three things, low pressure, trapped air, or a failing circulator. A gauge that reads below about 12 psi cold means the system is losing water somewhere or the fill valve is not doing its job. Cold radiators at the top of the house with a warm boiler usually means air in the loop.

Annual Service Items

  • Combustion analysis and burner cleaning.
  • Verify expansion tank pre-charge with the system depressurized.
  • Test the low-water cutoff and pressure relief valve.
  • Inspect circulator pumps for noise, heat, and flange leaks.
  • Flush or treat the loop where water quality calls for it.
  • Test glycol concentration and pH on antifreeze systems.

Glycol Systems and Freeze Protection

Any loop running through unheated space, a crawlspace, a shop, or snowmelt tubing, should carry properly inhibited glycol at a tested concentration. Inhibitors deplete over time and untested glycol can turn acidic and attack the system from the inside. We test concentration and pH during annual service.

Signs You Should Call

Repeated pressure loss, visible weeping at fittings, banging or gurgling in the pipes, short cycling, or a boiler that will not maintain setpoint on cold days are all worth a service call before deep winter.

Talk to a Moore Heating Technician

If you want a second opinion on your own system, call (907) 561-1500 or send us a message. We serve Anchorage, the Mat-Su Valley, and the Fairbanks area, and we have been doing it since 1974.

Frequently Asked Questions

What Pressure Should My Boiler Run At?

Most residential systems sit near 12 to 15 psi cold and rise modestly when hot. Consistent drift outside that range points to an expansion tank or leak issue.

How Long Do Boilers Last in Alaska?

Twenty to thirty years is common with annual service and good water quality. Cast iron units often run longer than that, with efficiency the reason to replace rather than failure.

Why Are Some Radiators Cold?

Usually trapped air, a closed zone valve, or a failing circulator. Bleeding high points is the first thing to try.